NPLA-HF – SoftForce Micro Platform-type Linear Actuator
- Miniature Size
- High Repeat Accuracy
- High-speed & Stable
- High Rigidity
RM-NPLA-HF SoftForce® Micro Platform-type Linear Actuator features miniature size, high repeat accuracy, high-speed & stable operation, and high rigidity. Ideal for precision automation applications.
Select models to quote
Add the models you need and request one quotation for all of them.
Product Model and Parameters (Applicable Sensor Range for HF50, HF100, HF200)
- RM-NPLA-10-30-1-HF
- RM-NPLA-10-30-2-HF
- RM-NPLA-10-30-4-HF
- RM-NPLA-10-30-6-HF
Product Model and Parameters (Applicable Sensor Range for HF50, HF100, HF200)
- RM-NPLA-10-50-1-HF
- RM-NPLA-10-50-2-HF
- RM-NPLA-10-50-4-HF
- RM-NPLA-10-50-6-HF
Product Model and Parameters (Applicable Sensor Range for HF10)
- RM-NPLA-10-30-2-HF10
- RM-NPLA-10-30-4-HF10
- RM-NPLA-10-30-6-HF10
- RM-NPLA-10-50-2-HF10
- RM-NPLA-10-50-4-HF10
- RM-NPLA-10-50-6-HF10
Product Model and Parameters (Applicable Sensor Range for HF50, HF100, HF200, HF300)
- RM-NPLA-16-75-5-HF
- RM-NPLA-16-75-10-HF
- RM-NPLA-16-150-5-HF
- RM-NPLA-16-150-10-HF

Product Model and Parameters (Applicable Sensor Range for HF50, HF100, HF200)
| Model | RM-NPLA-10-30-1-HF | RM-NPLA-10-30-2-HF | RM-NPLA-10-30-4-HF | RM-NPLA-10-30-6-HF |
|---|---|---|---|---|
| Size Code | 10 | 10 | 10 | 10 |
| Weight (kg) | 0.7 | 0.7 | 0.7 | 0.7 |
| Dimensions (mm) | 156.5*35*48 | 156.5*35*48 | 156.5*35*48 | 156.5*35*48 |
| Performance | ||||
| Stroke (mm) | 30 | 30 | 30 | 30 |
| Lead (mm) | 1 | 2 | 4 | 6 |
| Max. Speed (mm/s) | 50 | 100 | 200 | 300 |
| Max. Load (kg) | ||||
| Horizontal | 2 | 2 | 2 | 1.5 |
| Vertical | 3 | 2 | 1 | 0.75 |
| Repeat Positioning Accuracy (mm) | ±0.005 | ±0.005 | ±0.005 | ±0.005 |
| Control | ||||
| Compatible Controllers | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF |
| Supporting Communication Methods | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU |
| Operating Environment | ||||
| Rated Voltage (V) | DC24±10% | DC24±10% | DC24±10% | DC24±10% |
| Rated Current (A) | 1.25 | 1.25 | 1.25 | 1.25 |
| Usage Environment | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) |
| Protection Class IP | IP40 | IP40 | IP40 | IP40 |
Scroll the table sideways to see every model.
Product Model and Parameters (Applicable Sensor Range for HF50, HF100, HF200)
| Model | RM-NPLA-10-50-1-HF | RM-NPLA-10-50-2-HF | RM-NPLA-10-50-4-HF | RM-NPLA-10-50-6-HF |
|---|---|---|---|---|
| Size Code | 10 | 10 | 10 | 10 |
| Weight (kg) | 0.8 | 0.8 | 0.8 | 0.8 |
| Dimensions (mm) | 176*35*48 | 176*35*48 | 176*35*48 | 176*35*48 |
| Performance | ||||
| Stroke (mm) | 50 | 50 | 50 | 50 |
| Lead (mm) | 1 | 2 | 4 | 6 |
| Max. Speed (mm/s) | 50 | 100 | 200 | 300 |
| Max. Load (kg) | ||||
| Horizontal | 2 | 2 | 2 | 1.5 |
| Vertical | 3 | 2 | 1 | 0.75 |
| Repeat Positioning Accuracy (mm) | ±0.005 | ±0.005 | ±0.005 | ±0.005 |
| Control | ||||
| Compatible Controllers | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF |
| Supporting Communication Methods | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU |
| Operating Environment | ||||
| Rated Voltage (V) | DC24±10% | DC24±10% | DC24±10% | DC24±10% |
| Rated Current (A) | 1.25 | 1.25 | 1.25 | 1.25 |
| Usage Environment | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) |
| Protection Class IP | IP40 | IP40 | IP40 | IP40 |
Scroll the table sideways to see every model.
Product Model and Parameters (Applicable Sensor Range for HF10)
| Model | RM-NPLA-10-30-2-HF10 | RM-NPLA-10-30-4-HF10 | RM-NPLA-10-30-6-HF10 | RM-NPLA-10-50-2-HF10 | RM-NPLA-10-50-4-HF10 | RM-NPLA-10-50-6-HF10 |
|---|---|---|---|---|---|---|
| Size Code | 10 | 10 | 10 | 10 | 10 | 10 |
| Weight (kg) | 0.7 | 0.7 | 0.7 | 0.8 | 0.8 | 0.8 |
| Dimensions (mm) | 133.5*35*48 | 133.5*35*48 | 133.5*35*48 | 153.5*35*48 | 153.5*35*48 | 153.5*35*48 |
| Performance | ||||||
| Lead (mm) | 2 | 4 | 6 | 2 | 4 | 6 |
| Stroke (mm) | 30 | 30 | 30 | 50 | 50 | 50 |
| Max. Speed (mm/s) | 100 | 200 | 300 | 100 | 200 | 300 |
| Max. Load (kg) | ||||||
| Horizontal | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| Vertical | 0.5 | 0.3 | 0.3 | 0.5 | 0.3 | 0.3 |
| Repeat Positioning Accuracy (mm) | ±0.005 | ±0.005 | ±0.005 | ±0.005 | ±0.005 | ±0.005 |
| Control | ||||||
| Compatible Controllers | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF |
| Supporting Communication Methods | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU |
| Operating Environment | ||||||
| Rated Voltage (V) | DC24±10% | DC24±10% | DC24±10% | DC24±10% | DC24±10% | DC24±10% |
| Rated Current (A) | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 |
| Usage Environment | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) |
| Protection Class IP | IP40 | IP40 | IP40 | IP40 | IP40 | IP40 |
Scroll the table sideways to see every model.
Product Model and Parameters (Applicable Sensor Range for HF50, HF100, HF200, HF300)
| Model | RM-NPLA-16-75-5-HF | RM-NPLA-16-75-10-HF | RM-NPLA-16-150-5-HF | RM-NPLA-16-150-10-HF |
|---|---|---|---|---|
| Size Code | 16 | 16 | 16 | 16 |
| Weight (kg) | 1.6 | 1.6 | 2.2 | 2.2 |
| Dimensions (mm) | 209*58*63.5 | 209*58*63.5 | 282*58*63.5 | 282*58*63.5 |
| Performance | ||||
| Stroke (mm) | 75 | 75 | 150 | 150 |
| Lead (mm) | 5 | 10 | 5 | 10 |
| Max. Speed (mm/s) | 250 | 380 | 250 | 380 |
| Max. Load (kg) | ||||
| Horizontal | 3 | 3 | 3 | 3 |
| Vertical | 5 | 3 | 5 | 3 |
| Repeat Positioning Accuracy (mm) | ±0.02 | ±0.02 | ±0.02 | ±0.02 |
| Control | ||||
| Compatible Controllers | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF | RM-CEUF; RM-CEMF |
| Supporting Communication Methods | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU |
| Operating Environment | ||||
| Rated Voltage (V) | DC24±10% | DC24±10% | DC24±10% | DC24±10% |
| Rated Current (A) | 5 | 5 | 5 | 5 |
| Usage Environment | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) |
| Protection Class IP | IP40 | IP40 | IP40 | IP40 |
Scroll the table sideways to see every model.
Closed-Loop Output Range Table for Different Sensor Ranges
| Lead (mm) | Stroke (mm) | Closed-loop Output Range (N) HF10-0001 | Closed-loop Output Range (N) HF50-001 | Closed-loop Output Range (N) HF100-005 | Closed-loop Output Range (N) HF200-010 | Closed-loop Output Range (N) HF300-050 |
|---|---|---|---|---|---|---|
| 1 | 30、50 | / | 0.2 ~ 49.8 | 0.6 ~ 99.4 | 1.1 ~ 198.9 | / |
| 2 | 30、50 | 0.02 ~ 9.98 | 0.2 ~ 49.8 | 0.6 ~ 99.4 | / | / |
| 4 | 30、50 | 0.02 ~ 9.98 | 0.2 ~ 49.8 | / | / | / |
| 6 | 30、50 | 0.02 ~ 9.98 | 0.2 ~ 29.8 | / | / | / |
| 5 | 75、150 | / | 0.2 ~ 49.8 | 0.6 ~ 99.4 | 1.1 ~ 198.9 | 5.1 ~ 294.9 |
| 10 | 75、150 | / | 0.2 ~ 49.8 | 0.6 ~ 99.4 | 1.1 ~ 178.9 | / |
Scroll the table sideways to see every model.
Note: Test data measured at 25°C laboratory.