TWT Enterprise Co.,Ltd.

NPLA – Micro Platform Type Linear Actuator

  • Miniature Size
  • High Repeat Accuracy
  • High-speed & Stable
  • High Rigidity

RM-NPLA Micro Platform-type Linear Actuator features a compact design well-suited for factory automation. It offers multiple stroke and force options, high positioning repeatability and stable high-speed performance.

RM-NPLA-10-30 micro platform-type linear actuator, side view

Select models to quote

Add the models you need and request one quotation for all of them.

RM-NPLA-10-30 - Micro Platform-type Linear Actuator

  • RM-NPLA-10-30-1
  • RM-NPLA-10-30-2
  • RM-NPLA-10-30-4
  • RM-NPLA-10-30-6

RM-NPLA-10-50 - Micro Platform-type Linear Actuator

  • RM-NPLA-10-50-1
  • RM-NPLA-10-50-2
  • RM-NPLA-10-50-4
  • RM-NPLA-10-50-6

RM-NPLA-16-75/150 - Micro Platform-type Linear Actuator

  • RM-NPLA-16-75-5
  • RM-NPLA-16-75-10
  • RM-NPLA-16-150-5
  • RM-NPLA-16-150-10
NPLA Linear ActuatorNPLA Linear Actuator Wiring

RM-NPLA-10-30 - Micro Platform-type Linear Actuator

Specifications
Model RM-NPLA-10-30-1 RM-NPLA-10-30-2 RM-NPLA-10-30-4 RM-NPLA-10-30-6
Size Code10101010
Weight0.5 kg0.5 kg0.5 kg0.5 kg
Dimensions111.5*34*48 mm111.5*34*48 mm111.5*34*48 mm111.5*34*48 mm
Stroke30 mm30 mm30 mm30 mm
Lead1 mm2 mm4 mm6 mm
Max. speed50 mm/s100 mm/s200 mm/s300 mm/s
Max. Pushing Force210 N110 N50 N30 N
Max. Load Mass (Horizontal)6 kg3 kg2 kg1.5 kg
Max. Load Mass (Vertical)3 kg2 kg1 kg0.5 kg
Repeatability±0.005 mm±0.005 mm±0.005 mm±0.005 mm
Allowable Moment MP9.75 N.m9.75 N.m9.75 N.m9.75 N.m
Allowable Moment MR11.31 N.m11.31 N.m11.31 N.m11.31 N.m
Allowable Moment MY3.75 N.m3.75 N.m3.75 N.m3.75 N.m
Compatible ControllersRM-CEU; RM-CEMRM-CEU; RM-CEMRM-CEU; RM-CEMRM-CEU; RM-CEM
Communication ProtocolsRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-LinkRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-LinkRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-LinkRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-Link
I/O InterfaceSee controller specsSee controller specsSee controller specsSee controller specs
Operating VoltageDC 24V ±10%DC 24V ±10%DC 24V ±10%DC 24V ±10%
Rated Current1.25A1.25A1.25A1.25A
Cable Length3m / 5m3m / 5m3m / 5m3m / 5m
Operating Environment0~40℃, < 85%RH0~40℃, < 85%RH0~40℃, < 85%RH0~40℃, < 85%RH
Protection ClassIP40IP40IP40IP40

Scroll the table sideways to see every model.

RM-NPLA-10-50 - Micro Platform-type Linear Actuator

Specifications
Model RM-NPLA-10-50-1 RM-NPLA-10-50-2 RM-NPLA-10-50-4 RM-NPLA-10-50-6
Size Code10101010
Weight0.6 kg0.6 kg0.6 kg0.6 kg
Dimensions131.5*34*48 mm131.5*34*48 mm131.5*34*48 mm131.5*34*48 mm
Stroke50 mm50 mm50 mm50 mm
Lead1mm2 mm4 mm6 mm
Max. speed50 mm/s100 mm/s200 mm/s300 mm/s
Max. pushing Force210 N110 N50 N30 N
Max. Load Mass (Horizontal)6 kg3 kg2 kg1.5 kg
Max. Load Mass (Vertical)3 kg2 kg1 kg0.5 kg
Repeatability±0.005 mm±0.005 mm±0.005 mm±0.005 mm
Allowable Moment MP9.75 N.m9.75 N.m9.75 N.m9.75 N.m
Allowable Moment MR11.31 N.m11.31 N.m11.31 N.m11.31 N.m
Allowable Moment MY3.75 N.m3.75 N.m3.75 N.m3.75 N.m
Compatible ControllersRM-CEU; RM-CEMRM-CEU; RM-CEMRM-CEU; RM-CEMRM-CEU; RM-CEM
Communication ProtocolsRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-LinkRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-LinkRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-LinkRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-Link
I/O InterfaceSee controller specsSee controller specsSee controller specsSee controller specs
Operating VoltageDC 24V ±10%DC 24V ±10%DC 24V ±10%DC 24V ±10%
Rated Current1.25A1.25A1.25A1.25A
Cable Length3m / 5m3m / 5m3m / 5m3m / 5m
Operating Environment0~40℃, < 85%RH0~40℃, < 85%RH0~40℃, < 85%RH0~40℃, < 85%RH
Protection ClassIP40IP40IP40IP40

Scroll the table sideways to see every model.

RM-NPLA-16-75/150 - Micro Platform-type Linear Actuator

Specifications
Model RM-NPLA-16-75-5 RM-NPLA-16-75-10 RM-NPLA-16-150-5 RM-NPLA-16-150-10
Size Code16161616
Brake Weight1.4 kg1.4 kg1.9 kg1.9 kg
Dimensions164*58*63.5 mm164*58*63.5 mm237*58*63.5 mm237*58*63.5 mm
Stroke75 mm75 mm150 mm150 mm
Lead5 mm10 mm5 mm10 mm
Max. speed250 mm/s380 mm/s250 mm/s380 mm/s
Max. pushing Force360 N180 N360 N180 N
Max. Load Mass (Horizontal)18 kg15 kg18 kg15 kg
Max. Load Mass (Vertical)6 kg3 kg6 kg3 kg
Repeatability±0.02 mm±0.02 mm±0.02 mm±0.02 mm
Power-Off Self-LockingOptional BrakeOptional BrakeOptional BrakeOptional Brake
Allowable Moment MP18.13 N.m18.13 N.m18.13 N.m18.13 N.m
Allowable Moment MR19.11 N.m19.11 N.m19.11 N.m19.11 N.m
Allowable Moment MY18.13 N.m18.13 N.m18.13 N.m18.13 N.m
Compatible ControllersRM-CEU; RM-CEMRM-CEU; RM-CEMRM-CEU; RM-CEMRM-CEU; RM-CEM
Communication ProtocolsRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-LinkRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-LinkRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-LinkRM-CEU supports: EtherCAT; Modbus RTU; I/ORM-CEM supports: Modbus TCP; PROFINET; CC-Link
I/O InterfaceSee controller specsSee controller specsSee controller specsSee controller specs
Operating VoltageDC 24V ±10%DC 24V ±10%DC 24V ±10%DC 24V ±10%
Rated Current5A5A5A5A
Operating Environment0~40℃, < 85%RH0~40℃, < 85%RH0~40℃, < 85%RH0~40℃, < 85%RH
Protection ClassIP40IP40IP40IP40

Scroll the table sideways to see every model.

Note: Test data measured in lab at 25°C.