RM-PLA-HF – SoftForce® Straight Platform Linear Actuator
- Can be Installed Side-by-side
- High positioning repeatability
- Stable under High-speed
RM-PLA-HF SoftForce® Straight Platform Linear Actuator features side-by-side installation capability, high positioning repeatability, and stable high-speed operation. Ideal for precision automation applications.
Select models to quote
Add the models you need and request one quotation for all of them.
- RM-PLA-08-30-1-HF
- RM-PLA-08-50-1-HF
- RM-PLA-11-50-2-HF
- RM-PLA-11-100-2-HF

Product Specifications
| Model | RM-PLA-08-30-1-HF | RM-PLA-08-50-1-HF | RM-PLA-11-50-2-HF | RM-PLA-11-100-2-HF |
|---|---|---|---|---|
| Size Code | 08 | 08 | 11 | 11 |
| Weight (kg) | 0.5 | 0.7 | 1.0 | 1.2 |
| Dimensions (mm) | 193*25*44 | 213*25*44 | 300*37.5*50.5 | 350*37.5*50.5 |
| Performance | ||||
| Stroke (mm) | 30 | 50 | 50 | 100 |
| Lead (mm) | 1 | 1 | 2 | 2 |
| Max. Speed (mm/s) | 50 | 50 | 100 | 100 |
| Max. Load (kg) — Horizontal | 0.5 | 0.5 | 0.5 | 0.5 |
| Max. Load (kg) — Vertical | 1 | 1 | 1.5 | 1.5 |
| Repeat Positioning Accuracy (mm) | ±0.02 | ±0.02 | ±0.02 | ±0.02 |
| Control | ||||
| Compatible Controllers | RM-CEPF-20; RM-CEMSF-20 | RM-CEPF-20; RM-CEMSF-20 | RM-CEPF-20; RM-CEMSF-20 | RM-CEPF-20; RM-CEMSF-20 |
| Supporting Communication Methods | RM-CEPF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMSF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEPF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMSF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEPF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMSF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU | RM-CEPF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMSF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU |
| Operating Environment | ||||
| Rated Voltage (V) | DC24±10% | DC24±10% | DC24±10% | DC24±10% |
| Rated Current (A) | 2 | 2 | 2 | 2 |
| Usage Environment | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) | 0~40°C, < 85%RH (Non-condensing) |
| Protection Class IP | IP40 | IP40 | IP40 | IP40 |
Scroll the table sideways to see every model.
Closed-Loop Output Range Table for Different Sensor Ranges
| Size Code | Stroke (mm) | Closed-loop Output Range (N) HF10-0001 | Closed-loop Output Range (N) HF50-001 | Closed-loop Output Range (N) HF100-010 | Closed-loop Output Range (N) HF200-020 |
|---|---|---|---|---|---|
| 08 | 30、50 | 0.02 ~ 9.98 | 0.2 ~ 38.5 | / | / |
| 11 | 50、100 | / | 0.2 ~ 49.8 | 1.1 ~ 98.9 | 2.1 ~ 197.9 |
Scroll the table sideways to see every model.
Note: Test data measured at 25°C laboratory.