TWT Enterprise Co.,Ltd.

RM-PLA-HF – SoftForce® Straight Platform Linear Actuator

  • Can be Installed Side-by-side
  • High positioning repeatability
  • Stable under High-speed

RM-PLA-HF SoftForce® Straight Platform Linear Actuator features side-by-side installation capability, high positioning repeatability, and stable high-speed operation. Ideal for precision automation applications.

PLA Linear Actuator

Select models to quote

Add the models you need and request one quotation for all of them.

  • RM-PLA-08-30-1-HF
  • RM-PLA-08-50-1-HF
  • RM-PLA-11-50-2-HF
  • RM-PLA-11-100-2-HF
RM-PLA-HF SoftForce Straight Platform Linear Actuator — How to OrderRM-PLA-HF wiring diagram

Product Specifications

Model RM-PLA-08-30-1-HF RM-PLA-08-50-1-HF RM-PLA-11-50-2-HF RM-PLA-11-100-2-HF
Size Code08081111
Weight (kg)0.50.71.01.2
Dimensions (mm)193*25*44213*25*44300*37.5*50.5350*37.5*50.5
Performance
Stroke (mm)305050100
Lead (mm)1122
Max. Speed (mm/s)5050100100
Max. Load (kg) — Horizontal0.50.50.50.5
Max. Load (kg) — Vertical111.51.5
Repeat Positioning Accuracy (mm)±0.02±0.02±0.02±0.02
Control
Compatible ControllersRM-CEPF-20; RM-CEMSF-20RM-CEPF-20; RM-CEMSF-20RM-CEPF-20; RM-CEMSF-20RM-CEPF-20; RM-CEMSF-20
Supporting Communication MethodsRM-CEPF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMSF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTURM-CEPF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMSF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTURM-CEPF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMSF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTURM-CEPF controller supports: EtherCAT; Modbus RTU; I/O RM-CEMSF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU
Operating Environment
Rated Voltage (V)DC24±10%DC24±10%DC24±10%DC24±10%
Rated Current (A)2222
Usage Environment0~40°C, < 85%RH (Non-condensing)0~40°C, < 85%RH (Non-condensing)0~40°C, < 85%RH (Non-condensing)0~40°C, < 85%RH (Non-condensing)
Protection Class IPIP40IP40IP40IP40

Scroll the table sideways to see every model.

Closed-Loop Output Range Table for Different Sensor Ranges

Size Code Stroke (mm) Closed-loop Output Range (N) HF10-0001 Closed-loop Output Range (N) HF50-001 Closed-loop Output Range (N) HF100-010 Closed-loop Output Range (N) HF200-020
0830、500.02 ~ 9.980.2 ~ 38.5//
1150、100/0.2 ~ 49.81.1 ~ 98.92.1 ~ 197.9

Scroll the table sideways to see every model.

Note: Test data measured at 25°C laboratory.